for the online insulation testing of wire and cable industry. It can detect the defects such as pinhole, air gap and crack in the insulation layer of wire and cable surface invisible to the naked eye.
It has defect record and sound and light alarm system.When a defect is found, it will automatically record the defect data together and generate a sound and light alarm. It can also trigger the relay to control the external alarm system and send the defect record data to PLC or PC workstation through the rs-232/422/485 full-duplex serial port in time for online control.
Working conditions:
Model: GS-15 s
Power supply: AC200-240v 50/60hz
Ambient temperature: -5°C-50°C
Relative humidity: 20%-85%
Power: 150 w or less
Note: the spark should be grounded reliably
Technical indicators:
Output voltage: 0-15kv (sine wave with effective value)
Voltage display: 3-bit digital tube display 0.0-15.0kv, voltage regulation step length 100V
Number of defects display: 5-bit digital tube display
Test wire diameter: MAX25mm
Test frequency: 2500-3500hz, varying with the equivalent load capacitance
Electrode form: bead chain, in accordance with UL1581 standard
Electrode length: 50mm
Test mode: manual and automatic
Automatic leak detection recovery time: less than 20ms
Sensitivity: set 3KV, use the breakdown equipment to break down 20 times, not more than not more than remember, the breakdown current is no more than 600 A
Output current: 4mA resistive, 40mA capacitive
Maximum allowable linear speed: 3067m/min, in line with BS5099 and CCC standards1000m/min, in line with UL1581 and CSA standards
Output contact: 250V 2A
Serial communication: rs-232 rs-422 optional
Maximum communication range: 300m
Electrode cover safety interlock switch protection device